A detailed schematic of the complete JIGSAWS feature extraction, fusion, and prediction pipeline is shown in Fig. 1. This architecture demonstrates our multimodal design, where kinematic trajectories, heatmap density plots, task completion time, gesture event sequences, and video-based features are extracted and encoded via dedicated models (e.g., ResNet50, autoencoder, and SlowFast). The resulting features are concatenated, standardized, and passed to a 1D-CNN regression model to predict expert-assigned skill scores, enabling robust multimodal surgical skill assessment.
Fig. 1: Schematic of the complete JIGSAWS feature extraction, fusion, and prediction pipeline.
Video features are extracted using a pretrained SlowFast model and represented as visual features (V). Tool kinematic trajectories are converted into line plots and encoded with an autoencoder to generate kinematic features (K), while heatmap density plots are processed with ResNet50 to generate semantic density features (D). Task completion time (P) and encoded gesture sequence information (E) are also included. The fused multimodal representation is standardized, reduced using principal component analysis, and input to a 1-dimensional convolutional neural network to predict the Global Rating Scale score.
Similarly, Fig. 2 presents the architecture of our Biotissue pipeline, which adapts the same multimodal fusion strategy to robotic surgical training videos. Here, video-derived tool tracking (YOLOv8), RMS kinematic features, heatmap density plots, and deep visual encodings (ResNet50 and SlowFast) are extracted from robotic surgical training videos. These representations are likewise combined and fed as an input to a 1D-CNN to predict OSATS scores, demonstrating the framework’s flexibility for both robotic and non-robotic surgical data.
Fig. 2: Schematic of the complete Biotissue dataset (GJ and PJ) feature extraction, fusion, and prediction pipeline.
Surgical videos are processed using a YOLOv8-based tool tracking to derive motion trajectories. Visual features (V) are extracted using a pretrained SlowFast model, semantic density features (D) are obtained from heatmap density plots using ResNet50, and kinematic features (K) are derived from line plots encoded by an autoencoder together with root mean square kinematic features. These features are concatenated, standardized, reduced by principal component analysis, and used by a 1-dimensional convolutional neural network to predict the Objective Structured Assessment of Technical Skills score.
The proposed method should be understood as a modular multimodal assessment framework rather than as a single identical architecture instantiated across datasets. The overall design principle is consistent across both settings: modality-specific feature extraction, fusion of complementary representations, and downstream skill prediction. However, the exact modality branches are adapted to the signals available in each dataset. In the Biotissue dataset, only surgical videos and OSATS scores were available, whereas direct robotic kinematic streams, event annotations, and task-completion metadata were not available for direct integration (or were not perfectly aligned for use in the present assessment pipeline). Moreover, the videos contain practical imperfections, including pauses, variable zoom, and camera in/out motion. To address this, the framework derives motion-based tool-trajectory representations directly from video through segmentation, tracking, and trajectory extraction, thereby combining visual and video-derived kinematic information. In JIGSAWS, where richer modalities are directly available, these additional inputs can be incorporated explicitly within the same overall framework.
Tool segmentation and tracking
Instrument segmentation is performed using a YOLOv824 model, initialized with COCO25 pretrained weights and fine-tuned on a curated set of manually and semiautomatically (SAM2-assisted26) annotated frames.
The introduction of SAM2 substantially streamlined our annotation workflow. By using YOLOv8’s bounding-box predictions as prompts, SAM2 generates precise, instance-level masks with minimal human oversight. Enhanced pixel-level accuracy and fewer spurious segmentations have reduced the need for extensive manual frame selection, allowing us to annotate many more frames in less time and rapidly scale our training set27. Because SAM2 produces more precise and accurate tool masks (Fig. 3), the labels used for training are of higher quality. This enables the YOLOv8 model to learn from clearer, more correct examples, which improves its ability to identify and segment surgical tools in new images. The improvement is reflected in higher mAP@0.50–0.95 scores, a measure of how well the model detects and segments the tools. With these higher-quality labels and better scores, our final segmentation models become more robust and reliable for surgical video analysis.
Fig. 3: Segmentation output using SAM2-assisted annotation.
Representative segmentation output generated using the SAM2-assisted annotation workflow on a surgical training frame from the Biotissue dataset. Colored outlines and masks indicate the segmented tool components, including wrist, shaft, and jaw regions, which were used to improve annotation quality for downstream YOLOv8 segmentation model training.
For each video frame t, the model predicts bounding boxes and segmentation masks for all detected tool instances of the needle driver tool. The network is optimized to maximize both detection and segmentation performance, enabling accurate localization and pixel-wise delineation of multiple instruments per frame.
Detected tools are temporally linked across frames using BYTE Tracker, which associates bounding boxes based on spatial overlap and motion prediction. BYTE Tracker was selected for its demonstrated robustness to occlusion and real-time performance in surgical and cluttered scenes, as well as its superior tracking stability compared to prior approaches such as BotSort. These attributes make BYTE Tracker well-suited for the high-speed, multi-object tracking demands of surgical video analysis. For each tracked tool instance, the centroid ct,k = (xt,k,yt,k) of the corresponding mask is computed at each frame t. These centroid trajectories are then smoothed with a low-pass Butterworth filter (order n, cutoff frequency fc), yielding noise-reduced, temporally coherent motion paths suitable for downstream kinematic analysis. After segmentation and tracking, the trajectory data were post-processed to reduce the impact of missing detections, brief occlusions, identity inconsistencies, and short track fragmentation. Most missing detections occurred during temporary jaw occlusion, while more stable subparts, such as the wrist or shaft, remained detectable. Short gaps also arose when instruments moved partially out of the field of view, for example, during needle pickup or wider excursions associated with knot-tying. Left-right inconsistencies were corrected using the shaft as the primary anchor, together with spatial proximity, bounding-box overlap, and short-term temporal consistency across adjacent frames. Although these discrepancies can introduce local noise into the trajectories, their downstream impact is reduced because the final kinematic representation is derived from processed motion patterns rather than isolated single-frame detections.
For the JIGSAWS dataset, we utilize the synchronized two-dimensional (x, y) Cartesian coordinates of the tool tips, sampled at 30 Hz from the three patient side manipulators (PSM1, PSM2, and PSM3), which are the robotic arms of the da Vinci surgical system responsible for instrument manipulation at the patient bedside4. In the standard JIGSAWS protocols, only PSM1 and PSM2 (corresponding to the left and right primary instrument arms) are used for most tasks, while PSM3 is available but typically not analyzed. All coordinates are normalized to the [0, 1] range to ensure model compatibility and to emphasize relative motion dynamics over absolute spatial positioning.
Kinematic feature encoding using an autoencoder
Each tool-tip trajectory \({\left\{\left({{\mathscr{X}}}_{t},{{\mathscr{Y}}}_{t}\right)\right\}}_{t=1}^{T}\) is transformed into a pair of 1D line plot images: one representing the x-coordinate over time and the other the y-coordinate over time. These trajectory plot images, denoted as Itraj, are standardized and used as input to an autoencoder. This trajectory-to-image encoding strategy follows prior works, where x and y tool trajectories were similarly converted into plot-based representations and encoded with an autoencoder for surgical skill assessment11,27. In the present study, the same formulation was retained to provide a compact and consistent motion representation for downstream multimodal fusion across datasets. The purpose of this autoencoder module is to learn a compact, robust, and noise-resilient representation of tool-tip motion dynamics, capturing the most salient kinematic patterns for downstream skill assessment. The autoencoder fenc maps each plot image to a compact 256-dimensional latent feature vector z, while the decoder fdec reconstructs the original plot:
$${\bf{z}}={f}_{{enc}}\left({I}_{{traj}}\right),{I}_{{traj}}^{{\prime} }={f}_{{dec}}\left({\bf{z}}\right)$$
(1)
The autoencoder Fig. 4 is trained with a hybrid loss, combining mean squared error (MSE) and binary cross-entropy to promote both pixel-level accuracy and structural fidelity. The resulting latent vectors provide robust, noise-resilient encodings of tool motion dynamics, which are incorporated as features for downstream skill assessment.
$${{\mathscr{L}}}_{{\mathcal{h}}{\mathcal{y}}{\mathcal{b}}{\mathcal{r}}{\mathcal{i}}{\mathcal{d}}}={\text{MSE}}\left({I}_{{traj}},{I}_{{traj}}^{{\prime} }\right)+\lambda \cdot {\text{BCE}}\left({I}_{{traj}},{I}_{{traj}}^{{\prime} }\right)$$
(2)
Fig. 4: Autoencoder architecture.
The autoencoder is used for kinematic feature encoding. The encoder consists of four convolutional blocks with batch normalization, LeakyReLU activation, and max pooling, followed by a latent representation layer. The decoder reshapes the latent vector and reconstructs the input trajectory image through convolutional and upsampling blocks, ending with a sigmoid output layer. The latent representation is used as a compact feature encoding for downstream skill prediction.
Sequence encoder baselines
For the sequence encoder comparison, we additionally evaluated BiLSTM, TCN, and Transformer-based sequence encoders using the same video-derived tool trajectory inputs. Each input sequence had a fixed length of 512 timesteps with 12 trajectory channels corresponding to left and right tool-component coordinates. Each sequence encoder was trained within an autoencoder framework to reconstruct the input trajectory sequence using MSE loss. The encoder mapped each input trajectory sequence to a 128-dimensional latent representation, which was extracted and used as the kinematic trajectory feature in the downstream prediction pipeline. The models were trained using the AdamW optimizer, with early stopping based on validation reconstruction loss. The video feature branch, handcrafted kinematic statistics, downstream prediction model, cross-validation protocol, and evaluation metrics were kept unchanged across comparisons.
Spatio-temporal feature extraction using SlowFast-R50
To extract rich spatio-temporal representations from surgical video, we utilize the SlowFast-R50 neural architecture28, pretrained on the Kinetics-400 dataset. This model employs a dual-pathway design: the slow pathway captures spatial context by analyzing sparsely sampled frames, while the fast pathway focuses on densely sampled, rapid temporal dynamics. This enables simultaneous modeling of detailed spatial features and subtle motion, making it particularly effective for complex activities such as surgery.
We considered alternative video backbones, including Video Vision Transformer (ViViT)29, during model development. However, because our pipeline required repeated embedding extraction from long surgical videos across multiple experiments, transformer-based video models were substantially more computationally demanding under the available hardware constraints. We therefore selected SlowFast-R50 as a practical compromise between computational efficiency and spatio-temporal representation quality. Its dual-pathway design was also well-suited to surgical video, as it captures both slower contextual information and faster instrument-motion dynamics. We did not perform a systematic backbone ablation across all modalities in the present study, and this is a design choice based on feasibility and task suitability rather than a definitive superiority claim.
Given a sequence of raw video frames \({x}_{1},{x}_{2},\ldots ,{x}_{L}\), the SlowFast model processes the input in parallel as follows:
$${\rm{Slow\; pathway}}:{S}_{t}={\rm{Slow}}\left({x}_{1+a\left(t-1\right)}\right),\,t=1,2,\ldots ,T$$
(3)
$${\rm{Fast\; pathway}}:{F}_{l}={\rm{Fast}}\left({x}_{l}\right),\,l=1,2,\ldots ,L$$
(4)
where L is the total number of frames, \(T=\left[\frac{L-1}{\alpha }\right]+1\) is the number of slow pathway samples, and α is the temporal sampling ratio (e.g., α = 4). Feature maps from both pathways are fused at multiple stages, enabling the network to combine global context and detailed motion.
For downstream modeling, we divide each video into fixed-length segments Cm, then preprocess (resize and normalize) and extract a high-dimensional spatio-temporal embedding for each segment:
$${{\bf{f}}}_{m}={\rm{SlowFast}}\left({C}_{m}\right)$$
(5)
where \({{\bf{f}}}_{m}\in {{\rm{R}}}^{2048}\) represents the embedding for segment m. Segment embeddings are concatenated in temporal order and zero-padded to standardize input size, preserving the full sequence of spatio-temporal features:
$${{\bf{F}}}_{{\rm{video}}}=\left[{\bf{f}}1,{\rm{f}}2,\ldots ,{{\rm{f}}}_{N}\right]$$
(6)
where N is the number of segments per video.
We selected SlowFast over alternative video architectures such as X3D30 and ViViTs29 because SlowFast provides a strong balance of spatial context, motion detail, and computational efficiency. X3D is highly efficient, but its uniform temporal sampling can miss subtle surgical motions, while ViViT requires substantially larger datasets and more computing to avoid overfitting. In contrast, SlowFast’s dual-pathway design offers rich, fine-grained spatio-temporal representations, making it particularly effective for complex activity recognition in real-world scenarios.
Kinematic feature extraction—RMS metrics and path length (Biotissue dataset only)
After smoothing Biotissue Gastrojejunostomy (GJ) tool-tip trajectories with a 24 Hz low-pass Butterworth filter, we quantified tool motion using RMS metrics and path length. Since precise tool-tip position data (for wrist, shaft, and jaw components) are available only in the Biotissue dataset and not in JIGSAWS, these motion features were extracted exclusively for Biotissue. For each tool component, we computed:
$${{\rm{RMS}}}_{{\rm{velocity}}}=\sqrt{\frac{1}{N}{\sum }_{i=1}^{N}{v}_{i}^{2}}$$
(7)
$${{\rm{RMS}}}_{{\rm{acceleration}}}=\sqrt{\frac{1}{N}{\sum }_{i=1}^{N}{a}_{i}^{2}}$$
(8)
$${{\rm{RMS}}}_{{\rm{jerk}}}=\sqrt{\frac{1}{N}{\sum }_{i=1}^{N}{j}_{i}^{2}}$$
(9)
Here, vi, ai, and ji denote instantaneous velocity, acceleration, and jerk values, respectively, and N represents the total number of sampled data points.
Additionally, we computed the total path length traversed by each tool component across the entire trajectory, reflecting overall movement efficiency and precision:
$${\rm{Path\; Length}}={\sum }_{i=1}^{N-1}\sqrt{{\left({x}_{i+1}-{x}_{i}\right)}^{2}+{\left({y}_{i+1}-{y}_{i}\right)}^{2}}$$
(10)
All these features summarize motion smoothness, steadiness, and efficiency, key indicators of surgical skill. Calculations were limited to the Biotissue dataset, as the normalized coordinates of JIGSAWS precluded meaningful computation of these metrics. All extracted values were integrated into our multimodal feature set for skill prediction.
Semantic feature extraction—heatmap density plots
To capture spatial behavioral patterns and tool motion distribution in surgical procedures, we generated two-dimensional heatmap density plots Fig. 5 from tool-tip positions and extracted high-level semantic features using a pretrained ResNet50 model. While the overall goal of semantic representation remained consistent across datasets, the methodology was tailored to data characteristics in the Biotissue and JIGSAWS datasets. In Biotissue, the presence of camera movement and frequent zoom changes can distort heatmap interpretation, making depth estimation a crucial direction for future work to accurately localize tool activity. In contrast, the JIGSAWS dataset benefits from a fixed camera, but the provided tool-tip positions are normalized Cartesian coordinates rather than absolute workspace locations, which may introduce additional noise. Despite these limitations, semantic features from heatmap representations provide useful contextual information in both datasets, offering notable value for the Biotissue dataset and contributing additional signal for JIGSAWS.
Fig. 5: Heatmap density plots.
Representative heatmap density plots generated from tool-tip motion trajectories in the Biotissue and JIGSAWS datasets. The left panel shows density maps for the Biotissue dataset in image-coordinate space, and the right panel shows density maps for the JIGSAWS dataset using normalized Cartesian coordinates. Blue corresponds to the left tool, and orange corresponds to the right tool. These density maps are used to capture spatial motion distribution for semantic feature extraction.
Event sequence encoding
When annotated surgical event or gesture sequences are available, we encode the gesture sequence for each video as a series of one-hot vectors. Let C denote the total number of gesture types, and N the number of gestures in a given video. Each gesture is mapped to a one-hot encoded vector of length C, indicating its category. The resulting N × C matrix is then flattened to yield a feature vector of length N × C, which is concatenated with other video- and kinematic-derived features for downstream modeling. To create fixed-length feature vectors suitable for modeling, each array is zero-padded to match the maximum number of gesture events observed for that specific task. This encoding preserves the order of gestures within the video, providing a compact representation of the procedural sequence.
Encoding event or gesture sequences in this way is crucial because the type, order, and transitions of gestures can reflect both the efficiency and strategy of surgical performance. Procedural flow, repetition, and deviations from standard gesture sequences are often key indicators of technical skill, efficiency, and error. By capturing this sequential information, the model can better distinguish skill levels, identify atypical performance patterns, and provide a richer context for automated skill assessment.
Example: One-hot encoding for gestures G12, G13, G14, G15, G11 (C = 15, N = 5)
Gesture order: G12, G13, G14, G15, G11

N = 5 (number of gestures in this example; one row per gesture)
Flattened array: (N × C = 5 × 15 = 75 elements, row-wise concatenation)
[0,0,0,0,0,0,0,0,0,0,0,1,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,1,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,1,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0,1,
0,0,0,0,0,0,0,0,0,0,1,0,0,0,0]
Multimodal feature fusion and skill score prediction
All feature vectors, including autoencoder latent codes, RMS/path metrics, semantic heatmaps, spatio-temporal SlowFast embeddings, and event sequence encodings, are concatenated to form a comprehensive multimodal representation:
$${{\bf{X}}}_{{\rm{fused}}}=\left({\bf{z}},{{\rm{RMS}}}_{{\rm{velocity}}},{{\rm{RMS}}}_{{\rm{acceleration}}},{{\rm{RMS}}}_{{\rm{jerk}}},{\rm{Path\; length}},s,f1,\ldots ,{f}_{{\rm{M}}},{\bf{E}}\right)$$
(11)
These features are standardized via z-score normalization, and dimensionality reduction (e.g., PCA retaining 99% variance) is applied prior to prediction.
PCA was used to compress the high-dimensional fused feature vectors into a tractable representation for downstream prediction. The subsequent 1D-CNN was used as a nonlinear prediction head over the reduced feature vector, and the PCA components were not interpreted as literal temporal steps. This design is also consistent with prior work using PCA-reduced representations followed by CNN-based modeling in other domains31, as well as with our own prior work using compact structured representations for CNN-based downstream prediction27.
A 1D-CNN is trained to regress the expert-assigned skill score: ŷ = R(Xfused)
The model is optimized by minimizing the MSE loss:
$${{\mathcal{L}}}_{{\rm{reg}}}=\frac{1}{N}{\sum }_{i=1}^{N}{\left({y}_{i}-\hat{{y}_{i}}\right)}^{2}$$
(12)
Evaluation protocol
The performance of our model is evaluated using both the SCC (ρ) and MAE. Specifically,
$$\rho =1-\frac{6{\sum }_{i=1}^{N}{d}_{i}^{2}}{N\left({N}^{2}-1\right)}$$
(13)
$${\rm{MAE}}=\frac{1}{N}{\sum }_{i=1}^{N}|{y}_{i}-\hat{{y}_{i}}|$$
(14)
where di is the difference between the ranks of the true and predicted scores for sample i, and n is the number of samples.
For the JIGSAWS dataset, evaluation is performed using both 4-fold cross-validation and LOUO splits. For the Biotissue dataset, we employ 5-fold cross-validation on the GJ subset. For the expanded PJ subset, a separate stratified 5-fold cross-validation analysis was performed as a task-specific evaluation. In line with the recommendations discussed by Anastasiou et al.13, we emphasize that while the SCC is widely adopted as the primary evaluation metric, it only measures the agreement in ranking between predicted and true scores and does not reflect the actual prediction error. As highlighted by Contra-Sformer13, a model can achieve a high SCC despite large absolute prediction errors, especially on small test sets. To address this limitation, we report both MAE per task and the standard deviation of MAE across all folds, providing a more complete picture of model performance.
JIGSAWS dataset
For benchmarking, we used the public JIGSAWS dataset4, comprising 206 stereo endoscopic videos of three simulated robotic tasks: suturing (78 videos), needle-passing (56), and knot-tying (72). Recordings were captured at 30 Hz and 640 × 480 resolution from two viewpoints; we analyzed only the “capture1” (left) videos, yielding 39 suturing, 28 needle-passing, and 36 knot-tying clips.
Each trial includes an expert-assigned GRS (range: 6–30). JIGSAWS provides frame-level gesture annotations (G1–G15; see Table 12) and synchronized kinematic data, enabling detailed motion analysis and robust model supervision. Gesture sequences were one-hot encoded for input features. Unlike the Biotissue dataset, JIGSAWS enables fine-grained procedural segmentation, though the absence of stereo camera calibration limits 3D reconstruction accuracy.
Table 12 JIGSAWS gesture index and description
For JIGSAWS, 4-fold cross-validation was performed (as no predefined folds exist), using balanced splits by task. To ensure a fair comparison, we followed the commonly adopted splits described in Tang et al.32 and Liu et al.10. The evaluation is based on SCCs between model predictions and expert ratings.
Biotissue dataset
Our primary clinical dataset comprises 205 high-resolution videos (1280 × 720 pixels) of anastomoses performed on synthetic hydrogel Biotissue models (Lifelike Biotissue, Inc.) using the DaVinci Xi robot, subdivided into three categories: 33 pancreaticojejunostomy, 44 hepaticojejunostomy, and 128 gastrojejunostomy recordings. All procedures were performed by surgical trainees under standard institutional protocols at UT Southwestern Medical Center. The video data were collected as part of a quality improvement project reviewed by the Institutional Review Board at UT Southwestern Medical Center (IRB No. Y1-21-507), which determined that the project did not meet the definition of human subjects research. For downstream skill assessment, the GJ analysis used the same 128 videos, whereas the PJ analysis used an expanded cohort of 170 videos, including the original 33 PJ recordings and additional videos collected subsequently.
Simulation-based surgical training has become an essential component of many curricula, enabling trainees to practice in a risk-free controlled environment33,34,35. At UT Southwestern, we have developed and validated a proficiency-based robotic surgery simulation curriculum that combines a virtual reality platform (SimNow) with dry-lab exercises, followed by procedure-specific Biotissue drills36,37,38,39,40. These performances are recorded and subsequently assessed using global (OSATS and the Global Evaluative Assessment of Robotic Skills) measures as well as task-specific metrics and gestures1,41,42,43. While effective, these manual evaluations are resource-intensive and time-consuming, which has limited their scalability. One of our prior video-based assessment studies demonstrated that technical proficiency in simulated gastrojejunostomy drills is closely correlated with operative performance in real clinical cases. Importantly, surgical trainees who achieved higher performance scores in simulation experienced higher performance in the operating room and a lower incidence of clinically relevant delayed gastric emptying19. All Biotissue videos were evaluated using the OSATS scoring framework. Because GJ, PJ, and HJ represent distinct procedural tasks with different workflows, motion characteristics, technical demands, and sources of difficulty, we treated downstream skill assessment as a task-specific prediction problem rather than training a single unified predictor across heterogeneous procedures. In the present study, we report results for both the GJ and PJ subsets. HJ was not included in the downstream skill assessment experiments because the number of available HJ videos was too limited for a stable evaluation. By contrast, the segmentation model was developed using data from multiple procedure types to improve the robustness of tool localization across the dataset.
OSATS-based video assessment for the Biotissue dataset was performed independently by two research fellows who had completed a standardized institutional training framework for performance assessment within our validated robotic surgery curriculum. Both graders applied the OSATS rubric independently. Inter-rater reliability was quantified using the intraclass correlation coefficient (ICC) and reported in our prior works19,20, which demonstrated good agreement (ICC = 0.86, 95% CI: 0.69–0.93; p < 0.001) for GJ and ICC of 0.74 (0.6–0.84; p < 0.05) for the PJ dataset. The two graders were blinded to each other’s evaluations, and the final score assigned to each video was computed as the average of the two ratings.
A total of 1239 frames spanning all procedure types were manually annotated by trained medical interns and surgical staff, with each needle driver segmented into wrist, shaft, and jaw (classified as left or right; see Fig. 6). To augment the training set, 152 pseudo-labeled images were generated using a semi-automated workflow: initial YOLOv824 segmentation followed by SAM226 refinement. Further augmentation was limited due to diminishing accuracy gains. The final dataset comprised 1391 training, 153 validation, and 308 test images. YOLOv8 was initialized with COCO-pretrained weights25 and fine-tuned on the Biotissue dataset. Segmentation performance was evaluated using mean average precision (mAP@0.50–0.95), which averages precision across IoU thresholds and is the standard metric for segmentation quality in computer vision.
Fig. 6: Representative YOLOv8-based tool tracking outputs in the Biotissue dataset.
Representative YOLOv8 tool tracking outputs from the Biotissue dataset. The left panel shows gastrojejunostomy examples, and the right panel shows pancreatojejunostomy examples. The figure illustrates tracked needle driver components in surgical video frames and highlights the visual outputs used for downstream trajectory extraction and motion analysis.
We focused skill assessment on the gastrojejunostomy procedure subset, which includes 128 recordings with OSATS scores (range: 7–35) assigned by board-certified surgeons across seven performance domains. To mitigate outlier effects, scores were clipped to 10–32, excluding the lowest and highest 10% of samples (see Fig. 7 for score distributions). We also evaluated skill assessment on an expanded pancreaticojejunostomy (PJ) subset comprising 170 videos with OSATS scores (range: 7–35) (see Fig. 8 for score distributions).
Fig. 7: Score distribution for gastrojejunostomy subset.
Distribution of Objective Structured Assessment of Technical Skills scores for the gastrojejunostomy subset of the Biotissue dataset. The left panel shows the original score distribution, and the right panel shows the clipped score distribution used for downstream analysis after exclusion of extreme values. The horizontal axis indicates score, and the vertical axis indicates the number of videos.
Fig. 8: Score distribution for pancreatojejunostomy subset.
Distribution of Objective Structured Assessment of Technical Skills scores for the pancreatojejunostomy subset of the Biotissue dataset. The histogram shows the score frequency across videos included in the pancreatojejunostomy analysis. The horizontal axis indicates score, and the vertical axis indicates frequency.
For the Biotissue experiments, model performance was evaluated separately for each task-specific subset. The GJ subset was evaluated using 5-fold cross-validation, whereas the PJ subset was evaluated using stratified 5-fold cross-validation to better preserve the distribution of OSATS scores across folds and reduce fold-level imbalance. Performance was assessed using SCC between predicted and expert-assigned scores.
Preprocessing
All multimodal features and target scores were systematically preprocessed to ensure normalized input scales, reduced dimensionality, and stable model convergence. For each dataset, the complete feature set included autoencoded kinematic features, RMS motion statistics (Biotissue only), semantic heatmap features, spatio-temporal SlowFast-R50 embeddings, and one-hot encoded gesture events (JIGSAWS only). All feature vectors were standardized using zero-mean, unit-variance scaling to prevent any single feature type from dominating the learning process.
Target variables (GRS for JIGSAWS and OSATS for Biotissue) were independently scaled to the [0, 1] range using Min-Max normalization.
In JIGSAWS, gesture event sequences were converted to one-hot encoded matrices, flattened, and concatenated with other features prior to scaling and PCA. For videos of varying lengths, zero-padding was employed to achieve consistent input dimensions for batch processing in the 1D-CNN. All fitted preprocessing scalers and PCA models were saved for each cross-validation fold to ensure reproducibility and robust evaluation.
To further reduce redundancy and computational overhead, PCA was applied to the standardized features, retaining 99% of the total variance. Table 13 provides a summary of the feature dimensions before and after this reduction for both datasets.
Table 13 Summary of multimodal feature dimensions before and after principal component analysis (PCA)1D-CNN training
The fused multimodal features, including spatio-temporal, semantic, and kinematic modalities, were used to train a 1D-CNN to predict surgical skill scores (GRS for JIGSAWS, OSATS for Biotissue). For model input, the PCA-transformed features representing 92 principal components for Biotissue GJ, 119 for Biotissue PJ and 29 for JIGSAWS were used as compact reduced representations for the Conv1D layers. This allows the network to identify hierarchical correlations between components that capture the most significant variance across the fused modalities (V, K, E, D, P). Figure 9 illustrates the network architecture.
Fig. 9: 1D-CNN architecture diagram.
Architecture of the 1-dimensional convolutional neural network used for skill score prediction. The model consists of three convolutional layers with kernel size 3 and SELU activation, each followed by max pooling, then flattening, a dense layer with 1024 units, dropout, and a final dense output layer for regression.
The 1D-CNN model architecture, as summarized in Table 14, consisted of:
Three Conv1D layers (with 64, 128, and 256 filters; kernel size 3; SELU activation; and L2 regularization)
MaxPooling1D layers after each convolution
A flattened layer
A fully connected dense layer (1024 units, SELU activation) followed by dropout (rate 0.2)
An output dense layer (1 unit) for regression
Table 14 Summary of model architectures and main parameters
Input features were reshaped (to samples, components, and channels) for the Conv1D layers, with PCA components treated as timesteps and the channel dimension set to one. Model training employed the Adam optimizer for GJ and JIGSAWS, and AdamW for PJ (learning rate = 0.0002) using MSE loss, for up to 1000 epochs, with early stopping (patience = 200) based on validation loss. Five-fold cross-validation was used for the Biotissue dataset and 4-fold cross-validation for JIGSAWS, with all trained models, scalers, and PCA objects saved per fold. Validation predictions were aggregated across folds to assess the model’s reliability in predicting expert-assigned surgical skill scores.
All experiments were conducted on a high-performance workstation equipped with an AMD Ryzen Threadripper PRO 5955WX 16-core processor (4.0 GHz, 128 GB RAM) and two NVIDIA RTX 4090 GPUs (24 GB VRAM each).