Multimodal AI Assesses Simulated Resuscitation but Misses Many Critical

Multimodal AI Assesses Simulated Resuscitation but Misses Many Critical

A multimodal artificial intelligence system evaluated on prerecorded cardiac arrest simulations reliably confirmed performed clinical actions but missed more than forty percent of critical omissions, according to an experimental pilot study published in Resuscitation Plus. Led by Pierre-Marc Dion, the research evaluated how Gemini 1.5 Pro scored team-leader performance during simulated resuscitation megacodes. Advanced cardiac life support training requires strict algorithmic adherence, swift decision-making, and coordinated team dynamics. While the multimodal model achieved a sensitivity of 0.98 for identifying executed actions, its specificity for detecting omitted actions was only 0.58. This produced an overall agreement with expert consensus of Cohen’s kappa 0.62, which is categorized as moderate and remains markedly below the agreement achieved between human instructors. The findings demonstrate that while multimodal foundation models can observe complex clinical simulations, their deficiency in detecting omissions precludes unsupervised assessment deployment.

Simulation-based education allows healthcare professionals to practice technical interventions and non-technical communication within safe, controlled environments. In advanced cardiac life support curricula, simulation reinforces guideline-directed interventions and team management, demonstrating clear links to improved resuscitation outcomes and interpersonal coordination during actual clinical arrests. Nevertheless, conventional simulation assessment relies almost exclusively on experienced human raters. This standard approach demands substantial faculty time, consumes extensive institutional resources, and frequently suffers from inter-rater inconsistency. Although structured checklists and validated rubrics have improved scoring uniformity, fundamental barriers surrounding scalability and reproducibility remain unresolved across medical education. These limitations present severe challenges in emergency medicine training programs, where trainees require frequent evaluations of acute resuscitation performance while teaching faculty face severe time constraints and clinical demands.

Recent advances in computational vision and natural language processing have spurred interest in using artificial intelligence to reduce these assessment burdens. Earlier studies examined automated evaluation in objective structured clinical examinations, showing mixed agreement with human examiners. In trials where multimodal systems graded recorded basic life support skills, models frequently awarded higher marks than human raters and demonstrated lower concordance on steps requiring auditory cues. Other models have analyzed video from surgical operations and trauma resuscitations, while language models have evaluated written simulation text. However, direct video-based artificial intelligence scoring of cardiac arrest simulations remained previously unevaluated. To resolve this question, researchers designed a pilot study to test whether a multimodal system could match expert scoring consistency on cardiac arrest megacodes while analyzing model error mechanisms, omission detection, and self-reported confidence.

Approved by the Ottawa Health Science Network Research Ethics Board and conducted in alignment with healthcare simulation reporting standards, the study utilized six scripted megacode scenarios comprising three ventricular fibrillation cases and three pulseless electrical activity cases. The scripts reflected three distinct clinical performance profiles: exemplar execution with zero omissions, technical guideline deficiencies, and non-technical communication failures. Each scenario featured a defined clinical background, timed deviations, and an established checklist answer key. Faculty physicians and residents performed the scenarios on April 24, 2025, at the University of Ottawa Skills and Simulation Centre using a high-fidelity SimMan 3G manikin. Unedited ten-minute recordings were captured via a fixed-position wide-angle DJI Action 2 camera with integrated audio microphones. Mirroring standard resuscitation certification protocols, evaluations focused solely on team-leader actions.

To generate a reliable reference standard, two experienced resuscitation instructors independently evaluated each recording. Both evaluators routinely employ the megacode rubric, understood the study aims, but remained blinded to the simulation scripts and scoring keys, receiving no extra calibration. The instructors utilized a binary checklist containing sixteen items for ventricular fibrillation and twelve items for pulseless electrical activity, totaling eighty-four scenario-item pairs. Independent expert scoring demonstrated strong inter-rater concordance at Cohen’s kappa 0.78, with disagreements arising on eight items. These eight discrepancies were resolved through direct consensus discussions, forming the final reference standard. This expert consensus aligned closely with the predetermined script answer keys, achieving Cohen’s kappa 0.81 across seventy-seven matching items.

Automated analysis took place in May 2025 using Gemini 1.5 Pro via Google AI Studio, the only publicly accessible architecture capable of processing video and audio synchronously. A standardized five-step prompt provided the model with official resuscitation guidelines, the clinical stem, the recorded video, and the checklist, requesting binary performance ratings, explanatory reasoning, and confidence scores from 0 to 100. To examine operational consistency across randomness thresholds, two independent operators ran each de-identified recording at temperatures of 0, 1.0, and 2.0 with default settings, producing thirty-six runs and 504 item ratings. Operators remained blinded to expert consensus scores, and each iteration occurred within fresh accounts with logging disabled. Each video analysis ingested approximately 177,000 input tokens at standard rates.

Across all pooled experimental runs, the model demonstrated moderate concordance with expert consensus, recording an overall Cohen’s kappa of 0.62 and a prevalence-adjusted Gwet’s AC1 of 0.77. The model’s agreement with individual experts reached kappa values of 0.53 and 0.59, remaining well below the 0.78 observed between human evaluators. When treating performed actions as positive events, the system showed a sensitivity of 0.98 alongside a specificity of 0.58. The positive predictive value stood at 0.84, while negative predictive value reached 0.93. Overall diagnostic accuracy measured eighty-six percent, outperforming a constant classifier that scores every action as performed, which achieved sixty-nine percent accuracy and an AC1 of 0.58.

Statistical outcomes revealed that baseline action prevalence and scenario composition exerted a profound influence on agreement measurements. Exemplar scenarios contained exclusively completed actions without omissions, generating an artificial intelligence sensitivity of 0.99. When researchers excluded these exemplar cases, agreement metrics dropped substantially, with Cohen’s kappa falling from 0.62 to 0.56 and Gwet’s AC1 declining from 0.77 to 0.60. Performance also diverged sharply across scenario deficiency categories. In non-technical deficiency scenarios, the model achieved a strong Cohen’s kappa of 0.73, with 0.96 sensitivity and 0.72 specificity. Conversely, in guideline-deviation scenarios, the system demonstrated its weakest performance, yielding a poor Cohen’s kappa of 0.42 and a specificity of 0.50, missing half of all technical omissions.

Granular item-level analysis highlighted marked contrasts between explicit verbal statements and complex temporal actions. The artificial intelligence model consistently identified explicit verbal omissions and clear guideline breaches. In both the incorrect epinephrine dose and absent team role assignment cases, the system correctly flagged the omissions across six of six runs. However, when errors involved subtle timing or procedural sequencing, the model repeatedly failed to identify deviations. In the ventricular fibrillation guideline scenario, the system credited rhythm recognition and return of spontaneous circulation detection across all six runs, despite expert consensus marking both as omitted. Furthermore, the model captured delayed defibrillation, prolonged compression interruptions, and incorrect drug-rhythm cycles in only one or two out of six runs.

Qualitative examination of the model’s written justifications exposed notable contradictions between observational notes and final ratings. In several instances, the system noted significant delays within its narrative text yet still credited the clinical action as performed on the checklist. In other cases, the model fabricated unobserved clinical actions, describing non-existent procedural steps alongside precise timestamps. An analysis of self-reported confidence values demonstrated minimal diagnostic utility. Although overcall errors had a marginally lower mean confidence than correct ratings at 93.6 versus 98.1, forty-eight percent of overcalls occurred at maximum confidence of 100. Furthermore, while confidence dropped significantly for mismatches in four of six pulseless electrical activity conditions, it showed no significant difference across ventricular fibrillation trials.

The authors noted that these performance patterns align with vision-language literature, where models describe anticipated actions rooted in prior medical training rather than direct audiovisual evidence. This tendency is exacerbated by ongoing computational difficulties in localizing dynamic actions across continuous timeframes. Adjusting decoding temperature failed to correct this bias, as specificity measured 0.54 at temperature 0, 0.58 at temperature 1.0, and 0.62 at temperature 2.0. The authors identified key methodological limitations, including the small sample of six scenarios conducted at a single simulation center, reliance on local faculty and residents, and a single camera and microphone setup that may have missed quiet verbal exchanges. Only team-leader actions were evaluated, raters lacked formal calibration, and testing was conducted post hoc on an unversioned commercial model.

Regarding educational application, the authors concluded that while multimodal artificial intelligence may eventually enhance assessment scalability, current omission detection rates prohibit unsupervised deployment. With the system missing over four in ten omitted actions, independent use poses a severe risk of erroneously validating deficient clinical practice. Instead, the authors proposed that models could function as assistive drafting tools, generating preliminary checklist ratings for faculty review to reduce grading workload while preserving expert oversight. Additionally, simulation-based training relies fundamentally on qualitative debriefing, a capability requiring distinct future validation. Future investigations must evaluate larger cohorts, compare multiple architectures, and refine scoring rubrics and prompting strategies to explicitly capture temporal execution, physical coordination, and procedural timing during acute resuscitation training.

Subject of Research: Multimodal artificial intelligence assessment of simulated cardiac arrest resuscitation performance

Article Title: Multimodal artificial intelligence assessment of simulated cardiac arrest performance: a pilot study

Article References: Dion, P.-M., Cardenas-Mancera, J., Touchie, C., LeBlanc, V., Mbadjeu, A., Nickel, C., Waldolf, R., Yoo, Y., Bergamascki, L., Sekhavati, P., Crooks, S., & Gu, Y. (2026). Multimodal artificial intelligence assessment of simulated cardiac arrest performance: a pilot study. Resuscitation Plus, 32, Article 101517. https://doi.org/10.1016/j.resplu.2026.101517

Image Credits: AI Generated

DOI: 10.1016/j.resplu.2026.101517

Keywords: cardiac arrest simulation, multimodal artificial intelligence, advanced cardiac life support, megacode assessment, resuscitation training, Gemini 1.5 Pro, video-based assessment, objective structured clinical examinations, ventricular fibrillation, pulseless electrical activity, inter-rater agreement, Cohen’s kappa, Gwet’s AC1, omitted clinical actions, SimMan 3G, clinical skills evaluation, defibrillation timing, high-quality CPR