A scoping review of explainable artificial intelligence for medical multimodal data

A scoping review of explainable artificial intelligence for medical multimodal data

Study Selection

The initial search yielded 2521 records from Scopus (n = 1137), PubMed (n = 418), Web of Science (n = 698), and IEEE Xplore (n = 268). After removing duplicates, undertaking title and abstract screening, and reviewing full text for eligibility, 82 papers were included in the review (Fig. 1). The articles were excluded in title and abstract screening stage if: (1) Identified as review, editorial, or proposal (n = 218); (2) Missing XAI components or not explicitly mentioning XAI (n = 179); (3) Not related to disease detection tasks (n = 164); (4) Listing XAI or multimodal as a future direction (n = 122); (5) Identified as non-medical paper (n = 68); (6) Not using multimodal input data (n = 47); (7) Title not matching abstract (n = 1). The articles were excluded in the full-text screening stage if: (8) Failed to retrieve (n = 2); (9) Main focus is not multimodal XAI (n = 342); (10) Used only existing off-shelf models (n = 22); (11) Actual input is not multimodal (n = 18); (12) Not discussing details of XAI implementation (n = 1).

Fig. 1Fig. 1

PRISMA flow diagram for article identification, screening, and inclusion.

Study characteristics

Across the 82 included studies on clinical multimodal XAI for disease detection, we observe growing interest in XAI for multimodal AI, with a sharp increase in 2022 (n = 15), followed by a decline in 2023 (n = 6), then a rise in 2024 (n = 14), and the highest number in 2025 (n = 35) despite the cut-off date of October 2025 in our study selection criteria (Fig. 2a). The small number of publications prior to 2020 (n = 1 in both 2016 and 2019) reflects the recency of multimodal XAI research. Notably, clinical venues have dominated publication output in recent years, particularly in 2024 and 2025. The venue categorisation adhered to Google Scholar publication categorisation. Studies are published primarily in journals (n = 59) rather than in conferences (n = 23), with clinical venues accounting for a larger proportion of journal publications, whereas computer science venues dominate conference proceedings (Fig. 2b). These trends highlight the continuous developments in multimodal XAI technology with growing interests in clinical applications and adoption. Analysis of modality count (Fig. 2c) reveals that integrating three data sources was the most common approach (n = 35), followed closely by dual-modality models (n = 33), while a smaller subset of studies (n = 14) explored complex fusions of four or more modalities.

Fig. 2: Overview of included studies on clinical multimodal XAI for disease detection.Fig. 2: Overview of included studies on clinical multimodal XAI for disease detection.

a Temporal distribution of the 82 included studies from 2016 to 2025, stratified by the publication venue category (clinical journals/conferences versus computer science journals/conferences) in which each study appeared. b Publication venue type distribution (journal versus conference), stratified by venue category as in a. c Distribution of studies by number of integrated modalities. All three panels describe the included clinical disease-detection studies, not multimodal XAI as a whole.

MM XAI topic modelling

The Sankey diagram (Fig. 3) illustrates the relationships between clinical disease categories, XAI technology types, and multimodal data combinations across the 82 included studies. Clinical disease categories were classified according to standard medical specialties, resulting in 14 distinct domains. Modality combinations were grouped into 17 categories, with MRI-based configurations representing the most common data integration approach.

Fig. 3: Sankey diagram of studies across medical domains, XAI technology types, and modality combinations.Fig. 3: Sankey diagram of studies across medical domains, XAI technology types, and modality combinations.

The three-column flow visualisation depicts the relationships among clinical disease categories (left), multimodal XAI technology types (centre), and data-modality combinations (right) for the 82 included studies. Node heights are proportional to study counts, with values indicated in parentheses. Flow widths denote the number of studies that share each combination of attributes.

Four major types of multimodal XAI technology types were identified and categorised by the depth of their explanation of the reasoning process and modality interaction, ranging from isolated feature attribution to reasoning narrative generation (see Categorising multimodal XAI technologies). Type 1, Independent Feature Attribution (n = 37), represents the most prevalent approach22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58. Type 2, Cross-Modal Alignment (n = 30), captures methods that explicitly model relationships between modalities13,59,60,61,62,63,64,65,66,67,68,69,70,71,72,73,74,75,76,77,78,79,80,81,82,83,84,85,86,87. Type 3, Concept-Based Reasoning (n = 13), encompasses techniques that map predictions to human-interpretable concepts88,89,90,91,92,93,94,95,96,97,98,99,100. Type 4, Holistic Multimodal Reasoning (n = 2), represents emerging approaches that generate cohesive explanations integrating all modalities101,102.

Regarding multimodal data combinations, MRI-based configurations were predominant across the literature. Studies utilising MRIs or in combination with other modalities accounted for the largest share (n = 38)13,23,25,28,30,31,32,33,34,35,38,42,46,47,49,50,54,57,58,59,60,63,66,67,69,73,76,80,84,85,86,87,92,95,96,97,98,99. Beyond MRI combinations, clinical data combinations (n = 7)26,28,37,59,65,81,101, X-ray with text reports (n = 6)40,72,74,78,83,102, genomics combinations (n = 5)27,51,64,68,100, histopathology combinations (n = 5)36,55,61,64,71, and X-ray combinations (n = 5)22,24,43,44,90 were also represented. Less frequent combinations included CT-based configurations (n = 3)45,53,76, text combinations (n = 2)29,82, signal-based data such as EEG and ECG (n = 2)70,93, and ultrasound combinations (n = 2)48,91. MRI + Other group (n = 3) comprises MRI paired with intraoperative ultrasound, psychometric questionnaire data, or a generically labelled ‘medical imaging’ input. X-ray + Text (n = 6) refers exclusively to chest X-rays paired with free-text radiology reports (one study additionally including eye-gaze data), while X-ray combinations (n = 5) group X-ray with clinical data, demographics, ultrasound, or eye-gaze recordings. Histopathology combinations (n = 5) cover whole-slide images paired with genomics, clinical data, or demographics, including one study using multiple WSI inputs only. Genomics combinations (n = 5) cover genomics paired with clinical, demographic, or neuroimaging data, including two studies using multiple genomic platforms only. CT combinations (n = 3) cover CT paired with PET, demographics, or genomics. Clinical combinations (n = 7) cover clinical/EHR data paired with text, demographics, signals, or non-radiological photographs (e.g., facial images for pain estimation), without a primary radiological imaging modality. Text combinations (n = 2) cover text paired with endoscopic images, or with audio and photographs for stress detection. Signal combinations (n = 2) cover EEG- and ECG-based studies. Ultrasound combinations (n = 2) consist of two studies using multi-view ultrasound only. Finally, the residual Other category (n = 4) captures studies whose modality pairs sit outside these groupings, comprising two ophthalmology studies (fundus photography only; OCT paired with infrared retinal imaging), one dermatology study (dermoscopic plus simulated images), and one dental study fusing CNN-derived deep features with radiomic descriptors from dental radiographs. The complete per-study modality assignments are provided in Supplementary Table 2.

The flow visualisation reveals distinct patterns in the alignment of specific medical domains with particular XAI approaches and modality configurations. Neurology studies demonstrated the broadest distribution across all four XAI types and multiple modality combinations, reflecting the field’s maturity in multimodal integration. In contrast, several specialities, including dental/oral health, metabolic/endocrine disorders, and infectious diseases, each contributed only a single study, indicating potential areas for expanded research. The predominance of Independent Feature Attribution across most disease categories suggests that, while multimodal architectures are advancing, the explainability methods employed often remain limited to individual-modality contributions rather than capturing cross-modal interactions.

Categorising multimodal XAI technologies

We categorise the selected studies into a taxonomy comprising four distinct XAI technology types (Fig. 4). This framework is formalised along two primary axes—interaction depth, which measures the level of modality interaction (how different types of medical data relate and influence one another), and reasoning format, describing the output style (how closely the generated explanation matches the general logic of clinical procedures):

Type 1: Independent Feature Attribution (Fig. 4a) – comprises methods that analyse multimodal AIs by assigning importance scores to individual inputs, treating each modality as a distinct contributor to the decision-making process. These techniques primarily utilise standard post-hoc tools to isolate the contribution of specific modality, such as generating feature rankings for tabular data or saliency maps for images. Our review indicates that current approaches to multimodal interpretability largely depend on these established tools: SHAP (n = 21) and unimodal Grad-CAM (n = 17) are the most frequently employed methods, followed by LIME (n = 10). However, these saliency-based and additive attribution methods possess inherent limitations; they are often sensitive to input noise and may lack faithfulness103, meaning the highlighted regions do not always accurately reflect the features the model used for its internal decision-making. In a clinical context, such inconsistencies can lead to reliance on misleading visual artifacts rather than genuine pathological biomarkers104. This approach is most common in early-fusion or ensemble architectures. For instance, Jahan et al. (2025) utilise SHAP summary plots to rank the top essential features for disease identification. While effective at identifying bias or key biomarkers, these explanations often fail to explain the model’s interactions among the modalities28. It also carries a high risk of Shortcut Learning, where the model focuses on some specific but unrelated markers instead of the pathology fact.

Type 2: Cross-Modal Alignment (Fig. 4b) – moves beyond isolation to visualise the connection between modalities, typically appearing with models using attention mechanisms. These techniques are dominant in transformer-based architectures and work by highlighting a region in one modality (e.g. an image) that corresponds to a feature in another (e.g. text or signal). A representative example is Byeon et al. (2025), which utilises cross-attention maps to visualise the contribution of different MRI sequences. While this directly addresses modality interaction, it generally remains at the feature level instead of explaining the model’s reasoning process—indicating where the model is looking, but not necessarily why that alignment leads to a specific diagnostic conclusion13.

Type 3: Concept-Based Reasoning (Fig. 4c) – attempts to bridge the semantic gap by mapping raw data to human-understandable concepts before making a final prediction. These models often employ prototypes or rule-based bottlenecks to ensure the reasoning process aligns with medical standards, thereby mapping raw inputs to clinically meaningful attributes (e.g. tumour size, texture, enhancement pattern) before prediction. For example, Wang et al. (2023) uses prototype patches from the training set to explain the classification of lung diseases. By forcing the model to reason via concepts (e.g. ‘this looks like a tumour because it resembles this prototype’), these methods offer high transparency in the model reasoning process, though they often define concepts for each modality in isolation before the final decision40.

Type 4: Holistic Multimodal Reasoning (Fig. 4d) – represents the emerging frontier of multimodal medical XAI, providing an integrated diagnostic justification that blends multiple modalities to justify the decision. Unlike previous types that output heat maps or confidence scores, these models generate natural language or interactive dialogue. Yang et al. (2025) exemplify this with their work on Medvisiochat, which introduced textual diagnosis explanations grounded with visual bounding boxes simultaneously. This XAI type is the most recent and rarest (n = 2), aligned with the popularity of large language models, but offers the highest potential for clinical adoption, as it mimics the reasoning style of a human expert by synthesising disparate data points into a single, logical argument, covering both modality interaction and model reasoning process102.

Fig. 4: Schematic overview of four multimodal XAI technology types identified in this review.Fig. 4: Schematic overview of four multimodal XAI technology types identified in this review.

a Independent feature attribution; b cross-modal alignment; c concept-based reasoning; d holistic multimodal reasoning.

This classification distinguishes between ‘explainability’ (Type 1 and 2), which generates post-hoc justifications for existing models’ predictions, and intrinsic ‘interpretability’ (Type 3 and 4), where transparency is embedded into the model architectural design directly.

XAI comparison between multimodal to unimodal

We inspect the primary differences between unimodal and multimodal XAI to determine whether the inclusion of additional modalities enhances explainability of the prediction, or if it introduces complexity that obscures the reasoning chain. We further analyses the interpretability gap between generic ‘off-the-shelf’ explainability tools and tailored multimodal techniques, which directly indicate their influence on clinician verification speed and diagnostic safety in high-stakes environments.

Of the 82 included studies, 27 (32.9%) quantitatively evaluated this unimodal-multimodal shift using algorithmic metrics over various clinical applications (e.g. segmentation and classification). Evaluation metrics included Intersection-over-Union (IoU) and the Dice Coefficient to measure alignment with clinical ground truth, alongside Faithfulness (or Fidelity) to ensure the XAI output accurately reflects the model’s internal logic. Faithfulness is a measure of how accurately an explanation reflects the true decision-making process of the underlying model, measured by the drop of model accuracy when important features identified by XAI are perturbed.

The results demonstrate that switching to a multimodal XAI framework typically leads to superior explanation. Among the 27 studies with quantitative evaluations on the unimodal-multimodal shift, 18 reported that multimodal explanations achieved higher localisation scores than their unimodal counterparts 13,25,30,60,62,63,64,65,70,71,74,88,89,90,91,92,94,102. Here, localisation refers to the spatial precision with which an XAI method identifies the relevant clinical imaging regions—such as a specific tumour boundary or a lesion—within the input data. A prominent example is Ketabi et al. (2023), who found that incorporating radiology reports improved the overlap between attention maps and expert-annotated pathology by over 11% compared to a vision-only baseline74. This improvement stems from the ability of textual clinical reports to provide explicit linguistic ‘anchors’ for visual features; by projecting both modalities into a shared space, the attention mechanism can better align ambiguous visual pathology with established medical terminology. This improved overlap compared to the unimodal solution translates to a more reliable secondary source mimicking clinicians, as it reduces the frequency of false-positive highlights that can distract a clinician during time-sensitive reviews. Similarly, Yang et al. (2025) demonstrated that Large Multimodal Models (LMMs) using visual grounding provide significantly more precise diagnostic justifications by linking textual reasoning to specific image regions102. In practice, this grounded reasoning led to superior diagnostic justifications: it achieved a Mean Intersection over Union (mIoU) of 32.4% and an AP40 of 38.9%, significantly outperforming traditional CNN-based baselines. This demonstrates that holistic multimodal reasoning technologies introduce a significant gain in localisation precision.

For the 11 non-imaging studies identified in this review, which include clinical combinations26,28,37,59,65,81,101, signal-based data70,93, and text combinations29,82, the evaluation of the unimodal-to-multimodal shift transitioned from spatial localisation to feature stability and reasoning coherence. For instance, in signal-based architectures, multimodal integration was found to improve the stability of diagnostics compared to single-signal baselines93. Similarly, in studies combining EHR with clinical text, the inclusion of structured data served to reduce the variance of feature importance scores (e.g. SHAP values), providing a more robust and consistent justification for the model’s output than unimodal clinical reports alone29,81.

However, a ‘black box’ trade-off was identified in 9 of these 27 studies 42,43,44,45,46,48,49,53,68, where interpretability scores either stagnated or decreased. These studies, often utilising Independent Feature Attribution (Type 1 XAI technology), found that the increased architectural complexity resulted in fragmented or diluted feature importance maps46,48,68, indicating that predictive performance gains do not always translate to improved explanation utility. For clinicians, these fragmented unimodal heatmaps pose a serious safety risk by masking ‘shortcut learning’, where AI relies on non-pathology features instead of clinical biomarker features, which can lead to misdiagnosis12,105. Furthermore, such disconnected explanations from unimodal solutions will fail to meet the strict traceability and transparency requirements of regulations, including the 2024 EU AI Act11 and the 2025 FDA Draft Guidance106, which legally mandate that high-risk diagnostic software provide auditable evidence of its decision-making logic to ensure patient safety. For instance, Ketabi et al. (2023) observed a trade-off where XAI-based training, while improving explainability, resulted in a 1% decrease in classification AUC score74. While this reflects a marginal cost in predictive power, the resulting alignment with clinical ground truth suggests that the model is prioritising relevant biomarkers over shortcut features. This indicates that when properly integrated, multimodality not only provides a broader evidence base but also improves the qualitative utility of XAI performance and clinical safety by explicitly utilising modality interaction instead of relying on fragmented unimodal solutions.

Table 1 provides a structured assessment of the 27 studies that quantitatively evaluated the transition from unimodal to multimodal XAI. It characterises the relationship between XAI architectural design, reproducibility, impact on model performance, and limitations (see Supplementary Table 2 for complete information).

Table 1 Consolidated qualitative assessment of the 27 studies quantitatively evaluating the unimodal-to-multimodal XAI shift, characterised by methodology, reproducibility, and clinical quality constraintsMechanisms of explanation: from post-hoc feature attribution to intrinsically explainable reasoning and modality interaction

Medical XAI is shifting from simple feature attribution toward methods that emulate expert clinical reasoning. While traditional approaches like SHAP and LIME still dominate for explaining AI models, emerging strategies now integrate symbolic reasoning and explanation-guided learning to align model logic with medical knowledge. Within the subset of 27 comparison studies, 18 (66.7%) demonstrated a measurable gain in explanation quality when moving from unimodal to multimodal configurations. Among these 18 successful cases, Type 2 XAI technologies (Cross-Modal Alignment) were the most prevalent, as they are specifically designed to highlight the synergy between different data streams. Specifically, multimodal AI started to employ chain-of-thought and dialogue-based explanations to provide step-by-step diagnostic reasoning in studies starting 2024, including studies by Mohanty et al. (2025) and Yang et al. (2025)101,102. This shift reflects increasing interest in explanation methods that align with clinical reasoning in decision-making.

The primary distinction in how multimodal XAI is presented lies in whether the interpretability is retroactively applied or architecturally integrated. We found 51 studies (62.2%) applied post-hoc XAI methods, which interpret the model’s decision only after it has been made. They include heatmaps (n = 34) and ranking clinical features through attribution plots to highlight independent contributions. The most common techniques in this category include Grad-CAM and its variants (n = 24) for visual localisation, SHAP (n = 21) for global and local feature attribution, LIME (n = 10) for simplified local explanations, and LRP (n = 4) for pixel-wise relevance. These techniques are typically associated with Independent Feature Attribution technology (Type 1), as they often treat the model as a ‘black box’ and struggle to visualise the actual mathematical interplay between different data streams.

In contrast, the remaining studies (n = 31) used intrinsically interpretable models, where the explanation is derived directly from the model’s architecture. The shift toward higher-level reasoning (Types 2 through 4) is almost exclusively driven by these intrinsic designs. This includes Attention Mechanisms (n = 15), which visualise the weighting of specific modalities or time-steps during fusion. Other intrinsic approaches include Prototype Networks (n = 2) that reason by comparing inputs to learned examples, and Rule-based/Counterfactual frameworks (n = 4) that generate textual or logical justifications, which offered higher-level reasoning (categorised into Type 3) but were far less common than standard attention maps. The other studies (n = 10) applied Custom Architecture-Specific Designs such as sparse coding and graph networks.

The choice of XAI technique is intrinsically constrained by the underlying fusion architecture (see Table 2). Early fusion models, which merge raw data at the input stage, predominantly exist in Type 1 (Independent Feature Attribution) XAI technique. In clinical applications, this offers high transparency of raw data inputs, which is beneficial for simple diagnostic tasks. Because modalities are combined before high-level feature extraction, explainability is often limited to post-hoc attributions that fail to capture cross-modal synergy. In contrast, intermediate fusion—common in transformer-based architectures—enables Type 2 (Cross-Modal Alignment) by allowing XAI to extract interaction weights (e.g. attention maps) from the latent space, which makes the models capable of visualising which imaging features correlate with specific clinical biomarkers.

Table 2 The Interplay Between Fusion Paradigms and XAI Reasoning Types

While late fusion provides clear modality-specific attribution, it often results in ‘additive’ rather than ‘integrative’ reasoning, as explanations are generated for isolated decisions before being ensembled, making them fail to explain the synergistic clinical intuition that arises when a physician synthesises disparate data40. Finally, the move toward Type 4 (Holistic Multimodal Reasoning) is driven by a special type of intermediate fusion—semantic fusion—in large language models. By projecting disparate data into a shared semantic space, these architectures bypass the structural limitations of traditional fusion strategies to provide integrated justifications in natural language.

Different fusion methods have different strengths and limitations in clinical settings since the interpretability bottleneck inherent in these architectures directly impacts clinical safety and auditability. While Early Fusion provides explainability at the feature level for clinicians, offering high transparency of raw data useful for simple diagnostic tasks, it is unable to capture cross-modal interactions, making it difficult for clinicians to identify shortcut learning issues, where a model may predict by relying on imaging artifacts rather than pathology facts. Intermediate Fusion is clinically valuable for visualising which specific features correlate with clinical biomarkers. However, a critical limitation is that these explanations can be abstract and feature-focused, making them harder for non-technical clinicians to verify inside the workflow. Conversely, Late Fusion offers superior modality-specific attribution, allowing a clinician to verify if a decision was driven by reliable or potentially noisy data. However, its ‘additive’ reasoning often fails to explain the synergistic intuition that arises when a physician synthesises disparate data. For high-stakes diagnostic reasoning, Holistic Multimodal Reasoning (Type 4) represents the most viable path for clinical adoption when compared to others. By utilising visual grounding, these systems reduce the ‘interpretive effort’ required by doctors, transforming abstract mathematical weights into actionable evidence that mimics a multidisciplinary clinical review. However, its risk of hallucinations makes strict human-in-the-loop verification workflows necessary.

Transparency in clinical workflow: evaluation and reproducibility of multimodal XAI

Regarding the evaluation of XAI technologies, 52 of 82 studies relied solely on qualitative, user-centred evaluation, involving visual inspection by authors or domain experts to confirm that highlighted regions (e.g. tumours) or selected features (e.g. specific genes) aligned with existing medical knowledge. 33 of 82 studies employed quantitative, algorithmic metrics, with a notable preference for standardised measures. In total, only 10 of 82 studies applied both qualitative and quantitative evaluations.

The most adopted algorithmic metrics include Intersection-over-Union (IoU) and Dice Coefficients (n = 14) for localisation accuracy, and Faithfulness/Fidelity Scores (n = 9) to measure how well the explanation tracks the model’s internal logic. Furthermore, ablation studies were used (n = 23) to prove that the interpretable components (like attention modules) improved model performance, while a minority of studies (n = 6) conducted formal user studies with medical professionals to assess the clinical utility of the explanations. Few studies (n = 7) provided no evaluation at all.

For study reproducibility, a total of 47 out of 82 studies used publicly available datasets. The most frequently adopted public datasets for surveyed studies include:

MIMIC (III, IV, or CXR): 13 studies (Clinical text and imaging).

ADNI (Alzheimer’s Disease Neuroimaging Initiative): 8 studies (MRI, PET, and clinical stats).

BraTS (Brain Tumor Segmentation): 6 studies (Multi-sequence MRI).

TCGA (The Cancer Genome Atlas): 5 studies (Pathology and genomic data).

We also provide the full inventory of all public and private datasets utilised across the 82 surveyed studies in Supplementary Table 2.

Conversely, 33 studies relied solely on private or restricted datasets (e.g. institutional data available only upon request), and 2 studies had no reference or unclear data availability.

Despite the wide adoption of public datasets, only 26 studies made their codebase publicly available (e.g. on GitHub), limiting the community’s ability to validate the specific implementation of multimodal AI and their XAI technologies.